:indicates performance within an expected performance level where the associated cornerstone objectives are met.
:represents performance outside an expected range of nominal utility performance but related cornerstone objectives are still being met.
:indicates related cornerstone objectives are being met, but with a minimal reduction in the safety margin.
:signals a significant reduction in safety margin in the area measured by the performance indicator.
The Thresholds of Performance Indicator
Last Update: Jan 11, 2024
Cornerstone | Performance Indicator | Thresholds | |||||
---|---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
||||
Mitigating Systems | The unavailability of safety system in the previous 12 quarters | All Plants | ≦2EDG | ≦2.5% | >2.5% | >5.0% | >10.0% |
>2EDG | ≦2.5% | >2.5% | >10.0% | >20.0% | |||
BWR | HPCS | ≦1.5% | >1.5% | >4.0% | >20.0% | ||
RHR | ≦1.5% | >1.5% | >5.0% | >10.0% | |||
The number of safety system functional failures in the previous 4 quarters | BWR | ≦6.0 | >6.0 | NA | NA | ||
Barrier Integrity | The percentage of Reactor Coolant System specific activity to the Technical Specification limit in the previous 4 quarters | ≦50.0% | >50.0% | >100.0% | NA | ||
Public Radiation Safety :The percentage of Reactor Coolant System leakage rate to the Technical Specification limit in the previous 4 quarters | ≦50.0% | >50.0% | >100.0% | NA | |||
Emergency Preparedness | Drill/Exercise Performance | ≧90% | ≧70% | <70% | NA | ||
Emergency Response Organization Drill Participation | ≧80% | ≧60% | <60% | NA | |||
Alert and Notification System Reliability | ≧94% | ≧90% | <90% | NA | |||
Occupational Radiation Safety |
Occupational Radiation Exposure Control Effectiveness in the previous 4 quarters | ≦2 | >2 | >5 | NA | ||
Public Radiation Safety |
The performance of the Radiological Effluent Control Program in the previous 4 quarters | ≦1 | >1 | >3 | NA |